Comprehensive Puncture and Percussion Training Model

The model is in supine position with the head turned to the left. Model has soft texture , realistic appearance. The top of this area is the puncture point. After the needle was inserted slightly outward, there was a sense of void and obvious blood return. After the puncture has successfully aspirated the fluid, do not withdraw the needle and push the fluid back in place. (As shown below) Turn back the two "plugs&quot. The model concentrates the essential puncture and aspiration skill set into one self-contained trainer.

Key Features

True-to-Life Anatomy

True-to-Life Anatomy

The model is in supine position with the head turned to the left.

Guided Skill Builder

Guided Skill Builder

Turn on pulse button. The pulse of the right carotid and femoral artery can be felt. When the carotid pulse is touched, the triangular area formed by the clavicular head of the sternocleidomastoid muscle, the sternal head, and the clavicle can be found. The top of this area is the puncture point. After the needle was inserted slightly outward, there was a sense of void and obvious blood return. After the puncture has successfully aspirated the fluid, do not withdraw the needle and push the fluid back in place. (As shown below) Turn back the two "plugs&quot. on the front and back of the operating table, the model can move up and down, and can take a semi-recumbent position. turn on the power button Percussion on the left side of the chest cavity, the solid sound can be obtained from the left anterior axillary line and below the midaxillary line. From the 6th to 7th intercostal space of the midaxillary line, the puncture needle is inserted vertically along the upper edge of the lower rib. A voice prompt of "wrong position, damaged nerves and blood vessels&quot. will be issued if the needle is inserted incorrectly. There is a sense of void and the pleural effusion can be withdrawn if the puncture has successfully aspirated the fluid, Push liquid back after practice. (As shown below).

Procedure Fidelity

Every key manipulation can be repeated until proficiency is reached.

Complete Training Kit

The kit includes the comprehensive puncture and percussion training model and its accessories, together with the accessories required to start training.

Standard Configuration

NO. Description QTY
1 Comprehensive Puncture and Percussion Manikin 1 PC
2 Operation table 1 PC
3 iliac bone module 2 PC
4 Simulated blood powder 1 BOT.
5 Simulated effusion 1 BOT.
6 50ml Syringe 1 PC
7 10ml Syringe 1 PC
8 Liquid-collecting bag 2 PC
9 Adapter 1 PC
Scroll to Top