Liver abscess puncture and thoracentesis simulator

The DM-CS6236 Liver abscess puncture and thoracentesis simulator: after each successful puncture and extraction, do not take out needle, push liquid back into model for repeating practice. Find liver pain point (between 8th and 9th rib), execute disinfection and prepare for operation, Turn on liver biopsy button. Follow instruction to practice. After the puncture, do not pull out the needle and push the liquid back in place. Exit or do not open the "liver puncture&quot. The model concentrates the essential puncture and aspiration skill set into one self-contained trainer.

Key Features

True-to-Life Anatomy

True-to-Life Anatomy

After each successful puncture and extraction, do not take out needle, push liquid back into model for repeating practice.

Guided Skill Builder

Guided Skill Builder

Find liver pain point (between 8th and 9th rib), execute disinfection and prepare for operation, Turn on liver biopsy button. Follow instruction to practice. The needle is correct, appear the feeling of disappointment and can pull out liver pus. After the puncture, do not pull out the needle and push the liquid back in place. Exit or do not open the "liver puncture&quot. button, and you can perform liver puncture and abscess training without breath-holding rhythm. Percussion on the left side of the chest cavity, the solid sound can be obtained from the left anterior axillary line and below the midaxillary line. From the 6th to 7th intercostal space of the midaxillary line, the puncture needle is inserted vertically along the upper edge of the lower rib. A voice prompt of "wrong position, damaged nerves and blood vessels&quot. will be issued if the needle is inserted incorrectly. There is a sense of void and the pleural effusion can be withdrawn if the puncture has successfully aspirated the fluid, Push liquid back after practice. (As shown below).

Procedure Fidelity

Accurate anatomical structure, clavicle, armpit, ribs and intercostal space can clearly palpable to locate and determine the puncture site;Practice liver abscess puncture, guided by voice indication, correct operation has realistic feedback with sense of empty and simulated liver abscess can be extracted. 2. Electronic monitoring:The needle should be pierced vertically along the upper edge of the lower rib, with voice prompt for puncture error.

Complete Training Kit

The kit includes the liver abscess puncture and thoracentesis simulator and its accessories, together with the accessories required to start training.

Standard Configuration

NO. Description QTY
1 Liver Abscess and Thorax Puncture Model 1 PC
2 Operation table 1 PC
3 Adapter 1 PC
4 50ml Syringe 1 PC
5 5ml Syringe 1 PC
6 Gauze 1 PC
7 Liquid-collecting bag 2 PC
8 Simulated effusion 1 BOT.
9 Dust cover 1 PC
Scroll to Top